Skip to content

Technical Data Overview

This section provides detailed technical specifications, performance data, and engineering requirements for all FullShop Gen 3 components, including:

  • System specifications
  • Performance metrics
  • Environmental requirements
  • Electrical specifications
  • Mechanical specifications
  • Communication protocols
SeriesFullShop Gen 3
Output (Fluids)Max Coolant Pressure: 145 psi
Max Water Pressure: 100 psi
Max Flow Water: 4 gpm
Max Coolant Flow: 0.8 gpm
Max Fluids Temp: 125 F
Piping Distance: See Plumbing Guidelines
ElectricalLine Voltage: 120 VAC nominal / Hertz: 60
Peak Full Load Amperage: 15 amps
Ratio Mixing Range0.5% to 20%
Max Inlet Hose Length10 ft
Water SourcesCompatible with: City/Tap, Reverse Osmosis, Deionized. User to provide water with reasonably low hardness. Our experience is <150 PPM hardness helps with long-term trouble-free operation. Water with higher hardness means more potential service issues due to scale and residue build up.
WeightDFU 55 lbs
SVI 0.75 lbs
DFU internet ConnectionWireless using SSID and password. Joins existing Wi-Fi network as client. No open ports or hosted services. Secured, tokenized, short-lived authentication to cloud services. DFU reached out to the cloud, not vice versa.
DFU / SVI Wireless MeshSecure, Independent, hidden, dedicated Mesh Wi-Fi. using standard WPA2 network security among the mesh nodes to ensure communication security.