This guide covers the general settings and configuration options available in the FullShop Gen 3 software. Here you’ll find information about system preferences, user settings, and other configurable parameters.
My Account
Section titled “My Account”Video Link (EMAILS AND NOTIFICATIONS)
| Parameter / Function | Description |
|---|---|
| First Name | First name of user. |
| Last Name | Last name of user. |
| Email weekly summary | When checked, application sends a summary once per week. Based on machines users are subscribed to. |
| Email daily reminder | For the DFUs and machines to which you are subscribed, sends an email every morning with any alarms and warnings that have been triggered but not yet reset. |
| Email immediate notification | When checked, application sends emails on warnings and alarms when they are first triggered. Based on machines users are subscribed to. |
| Top off adjustment mode indicators | When enabled, User to see top off mode of each CNC on summary page. |
| Training mode | Users cannot submit or change data in this mode. Adds tooltips as well. |
| Shows the email that is being used for sending alerts and notifications. | |
| Shop | Shows the CNC shop user has selected. |
| Role | Shows the users’ current role. |
| Shop admin | Shows who the current admin is for your shop. |
| Shop admin email | Shows email of shop admin. |
| Join Another Shop | Allows users to join other shops. |
| SUBMIT | Used to save changes – if you X out of the menu your changes will not be saved |
Manage Users
Section titled “Manage Users”Video Overview - User Management
Video Overview - Promote, Demote, Remove Users
| Role / Feature | Description |
|---|---|
| Invite New Users | Invite users to join at app.168mfg.com. Send above website and an invite code to employees or partners you want to join your shop’s app. The same code can be used more than once, but only an active code will grant access. |
| Invite Codes | Can be deactivated or refreshed by admin. |
| Guest User Profile | Guests are able to view machine data but not create or edit any data. |
| Operator 1 User Profile | Operator 1 profiles can view machine data and create data points. CANNOT reset alarms |
| Operator 2 User Profile | Operator 2 profiles can view machine data and create data points. CAN reset alarms |
| Supervisor User Profile | Supervisors are able to view machine data, create data points, manage machine settings, manage shop settings, reset alarms, enable empty sump fills, use bleed out functions. |
| Admin User Profile | Only the shop admin can manage users, manage invite codes and edit/delete data points. |
Users In Your Shop
| Action | Description |
|---|---|
| Promote | Increments user to next higher level of permission. |
| Demote | Decrements user to next lower level of permission. |
| Remove from shop | Removes the user access to the applications. |
Shop Setup
Section titled “Shop Setup”| Parameter / Function | Description |
|---|---|
| Shop name | Current name of shop. |
| Default SVI Settings | |
| Top off adjustment mode | Selection defines how top off ratios are determined. - Manual: User manually sets top off ratio. - Suggest: From a refract reading the app will suggest top off ratio. Users can decline, accept, or modify. - Auto: From refract reading > App automatically adjusts top off ratio when new data is entered in. |
| Top off adjustment strategy | Sets top off strategy to CNC when in suggested or auto mode. - Less Aggressive: Smaller adjustments per adjustment - Default: Standard Algorithm - More Aggressive: Larger adjustments per adjustment |
| Default Coolant | |
| Coolant name | Name of coolant being used. (Found on SDS) |
| Coolant type | The mixture base of the coolant. - Soluble oil - Synthetic - Semi – Synthetic - Straight oil (Found on SDS) |
| Coolant refractive index | The coolant multiplier used when gathering concentration data. (Found on SDS) |
| Concentration boundaries |
| Upper alarm | Point system sends alarm notification and email. |
| Upper warning | Point system sends warning notification and email. |
| Target Value | The desired concentration value. |
| Lower warning | Point system sends warning notification and email. |
| Lower alarm | Point system sends alarm notification and email. |
| Concentration collection frequency | |
| Days without collection until warning | Point system sends warning notification and email. |
| Days without collection until alarm | Point system sends alarm notification and email. |
| pH boundaries | |
| Upper alarm | Point system sends alarm notification and email. |
| Upper warning | Point system sends warning notification and email. |
| Target value | The desired pH value. |
| Lower warning | Point system sends warning notification and email. |
| Lower alarm | Point system sends alarm notification and email. |
| pH collection frequency | |
| Days without collection until warning | Point system sends warning notification and email. |
| Days without collection until alarm | Point system sends alarm notification and email. |
| Sump cleanings | |
| Months until warning | Point system sends warning notification and email. |
| Months until alarm | Point system sends alarm notification and email. |
| SUBMIT | Used to save changes – if you X out of the menu your changes will not be saved |
DFU Setup
Section titled “DFU Setup”| Parameter / Function | Description |
|---|---|
| DFU Name | Set name of DFU. |
| DFU Settings | |
| Enabled | Toggle DFU on or off. If checked blue, DFU is enabled. |
| Enabled Status | Shows status of DFU. |
| Coolant Tank Monitoring | |
| Flood height (inches) | Max level of coolant container. |
| Level (inches) | Shows current coolant source level. |
| Low level warning (inches) | Point system sends warning notification and email. |
| Low level alarm (inches) | Point system sends alarm notification and email. |
| Bottom offset (inches) | Unique value to sensor and bracket used. Set at 0.0 when using factory provided sensors |
| Water Temperature Monitoring | (10-minute rolling average. Note that data may not be immediate at power up) |
| High temperature alarm | Point system sends alarm notification and email. |
| High temperature warning | Point system sends warning notification and email. |
| Low temperature warning | Point system sends warning notification and email. |
| Low temperature alarm | Point system sends alarm notification and email. |
| Water Hardness Monitoring | (10-minute rolling average. Note that data may not be immediate at power up) |
| High conductivity alarm | Point system sends alarm notification and email. |
| High conductivity warning | Point system sends warning notification and email. |
| Conductivity | Shows current water hardness value. |
| Low conductivity warning | Point system sends warning notification and email. |
| Low conductivity alarm | Point system sends alarm notification and email. |
| Coolant Pressure Monitoring | |
| High pressure alarm | Point system sends alarm notification/email. Triggers fill prevention. |
| High pressure warning | Point system sends warning notification and email. |
| Pressure | Coolant pressure at DFU output |
| Water Pressure Monitoring | |
| High pressure alarm | Point system sends alarm notification/email. Triggers fill prevention. |
| High pressure warning | Point system sends warning notification and email. |
| Pressure | Value of current water pressure. |
| Low pressure warning | Point system sends warning notification and email. |
| Low pressure alarm | Point system sends alarm notification and email. |
| Coolant specific gravity | |
| Coolant specific gravity | Coolant Specific Gravity, from coolant data sheet |
| EXPORT DFU AND SVI CONFIGUIRATION | Creates export file for offline archive |
| CONFIGURE DFU WIFI | Starts utility to make Wi-Fi connection to your SSID using password and user credential. Required USB cable to be physically connected. Detailed instruction will appear upon entry to utility. |
Machine Setup
Section titled “Machine Setup”| Parameter / Function | Description |
|---|---|
| SAVE | Saves all settings made / changed to the SVI. |
| DELETE | Deletes machine from application. Action cannot be undone! |
| Machine name | Created name for the CNC that will show up in summary page. |
| SVI Settings | |
| Digital Feed Unit (DFU) | Select DFU the SVI will connect to. |
| Sensor Valve Interface (SVI) | MAC address of the specific SVI used to communicate to the DFU. |
| PASTE SVI SETTINGS | Allows copied settings to be pasted to another SVI. |
| Bucket fill mode | Changes SVI to bucket fill mode. Refer to the “Bucket fill mode” table for more information. |
| SVI Mode | -CBE: Concentration by Entry. (manual entry) VIDEO OVERVIEW -CBS: Concentration by Sensor. (automatic entry) -PMK: Poor Mans Kit. (water only mode) -SENSE: Sensors only. (data collection only) |
| Refractometer Sensor | (Only used with CBS mode) The type of refractometer being used for data readings. |
| Enabled | Status of whether SVI is enabled or disabled. |
| Top off concentration | Current set value of top off concentration. |
| Max auto fill volume | The max number of gallons the DFU will use to fill a sump before stopping. Triggers fill prevention. |
| Max empty sump fill volume | The max number of gallons the DFU will use to fill an empty sump before stopping. Triggers fill prevention. |
| Max auto fill duration | Point system sends alarm notification/email. Triggers fill prevention. |
| Flood height | Used for scaling level sensor to sump. Defines 100% full. |
| High level alarm | Point system sends alarm notification/email. Triggers fill prevention. |
| High level warning | Point system sends warning notification and email. |
| Fill stop level | The level auto filling stops at |
| Level | Shows current level of coolant in the sump. |
| Fill start level | The level auto filling starts at |
| Low level warning | Point system sends warning notification and email. |
| Low level alarm | Point system sends alarm notification/email. Triggers fill prevention. |
| Bottom offset | Unique value to sensor and bracket used. Set at 0.0 inches when using OEM sensors. |
| High temperature alarm | Point system sends alarm notification and email. |
| High temperature warning | Point system sends warning notification and email. |
| Temperature | Shows the current temperature of CNC sump. |
| Low temperature warning | The low temperature value of a sump to send out a warning notification and email. |
| Low temperature alarm | The low temperature value of a sump to send out an enhanced notification and email. |
| Top off adjustment mode | Selection defines how top off ratios are determined. Manual: User manually sets top off ratio. Suggest: From a refract reading the app will suggest top off ratio. Users can decline, accept, or modify. Auto: From refract reading > App automatically adjusts top off ratio when new data is entered in. |
| Top off adjustment strategy | Sets top off strategy to CNC when in suggested or auto mode. Less Aggressive: Smaller adjustments per adjustment Default: Standard Algorithm More Aggressive: Larger adjustments per adjustment |
| Machine Groups |
Either:
- Start typing a new group name and press return.
- Select existing group from the list shown.
| Coolant Name | |
|---|---|
| Coolant Name | Name of coolant being used. (Found on SDS) |
| Coolant type | The mixture base of the coolant. - Soluble oil - Synthetic - Semi – Synthetic - Straight oil (Found on SDS) |
| Coolant Refractive Index | The coolant multiplier used when gathering concentration data. (Found on SDS) |
| Concentration boundaries | |
| Upper alarm | Point system sends alarm notification and email. (Rich Coolant) |
| Upper warning | Point system sends warning notification and email. (Rich Coolant) |
| Target Value | Desired concentration value for selected CNC. |
| Lower warning | Point system sends warning notification and email. (Lean Coolant) |
| Lower alarm | Point system sends alarm notification and email. (Lean Coolant) |
| Concentration collection frequency | |
| Days without collection until warning | Point system sends warning notification and email. |
| Days without collection until alarm | Point system sends alarm notification and email. |
| pH boundaries | |
| Upper alarm | Point system sends alarm notification and email. |
| Upper warning | Point system sends warning notification and email. |
| Target value | The desired pH value. |
| Lower warning | Point system sends warning notification and email. |
| Lower alarm | Point system sends alarm notification and email. |
| pH collection frequency | |
| Days without collection until warning | Point system sends warning notification and email. |
| Days without collection until alarm | Point system sends alarm notification and email. |
| Sump cleanings | |
| Months until warning | Number of months with no sump cleanings recorded to send out warning notification and email. |
| Months until alarm | Number of months with no sump cleanings recorded to send out enhanced alarm and email. |
Switch Shop
Section titled “Switch Shop”| Function | Description |
|---|---|
| Select shop | Shows what shops you have access to switch over too. |
| SWITCH | Switches user over to selected shop. |
Assigning Ownership
Section titled “Assigning Ownership”Prior to arrival you will need to establish who takes ownership of what is above. This step is important to long term success and if not